Removing Fixing High-Voltage Pcb - Canon imagePRESS 1135 Series Service Manual

Hide thumbs Also See for imagePRESS 1135 Series:
Table of Contents

Advertisement

4
Parts Replacement and Cleaning > PCB > Removing Fixing High-Voltage PCB

Removing Fixing High-Voltage PCB

<Preparation>
1) Open the Front Left Cover and the Front Right
Cover.
(Refer to page 4-54)
2) Pull Out Fixing Feed Unit.
(Refer to page 4-120)
3) Remove Secondary Transfer Outer Unit.
(Refer to page 4-86)
2) Remove the 3 connectors.
x3
4
Parts Replacement and Cleaning > PCB > Removing Fixing High-Voltage PCB
1) Remove the grounding wire.
• 1 screw
F-4-870
3) Remove the claw in 2 places, and remove the fixing high voltage PCB.
x2
4-382
F-4-869
Claw
F-4-871
4-382