Removing Secondary Transfer Inner Roller - Canon imagePRESS 1135 Series Service Manual

Hide thumbs Also See for imagePRESS 1135 Series:
Table of Contents

Advertisement

4
Parts Replacement and Cleaning > Periodic Replacing Parts, Durable Parts, Cleaning Parts > Removing Secondary Transfer Inner Roller

Removing Secondary Transfer Inner Roller

<Preparation>
1) Open the Front Left Cover and the Front Right
Cover.
(Refer to page 4-54)
2) Remove Process Unit Cover.
(Refer to page 4-71)
3) Pull Out ITB Unit.
(Refer to page 4-83)
4) Remove ITB Cleaning Unit.
(Refer to page 4-227)
5) Remove Patch Sensor Unit.
(Refer to page 4-88)
6) Remove ITB.
(Refer to page 4-219)
Caution :
Be careful not to touch the surface of secondary transfer inner roller because it
may cause the image failure.
4
Parts Replacement and Cleaning > Periodic Replacing Parts, Durable Parts, Cleaning Parts > Removing Secondary Transfer Inner Roller
1) Loosen the screw and remove the secondary transfer inner roller unit (including the secondary
transfer mounting plate).
• 1 screw
Secondary transfer
inner roller unit
F-4-454
Screw
F-4-453
2) Remove the secondary transfer inner roller.
4-217
Secondary transfer inner roller
F-4-455
4-217

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents