Detail
Code
Location
Item
Code
E102 0001
05
Title
Error in scanner EEPROM reading
Description
When an error is detected on the EEPROM reading of
of detection
polygon scanner.
Measures
1. Check the connector.
2. Replace the laser scanner unit.
3. Replace the DC controller PCB.
E110 0010
05
Title
Error in scanner motor (Drive fails to start.)
Description
When VLOCK signal cannot be detected during the FG
of detection
rotation of polygon scanner (either the VLOCK signal cannot
be detected within 7.5 sec from startup or VLOCK signal
cannot be detected for 1 sec continuously after the VLOCK
signal is detected once.).
"x" in the detailed code represents the numeric values.
Occurrence timing can be identified by this numeric values (for
design review). As a field remedy, laser scanner needs to be
replaced regardless of this numeric values.
Measures
1. Check the connector.
2. Replace the laser scanner unit.
3. Replace the DC controller PCB.
E110 0011
05
Title
Error in scanner motor (Revolution fails to reach the specified
value.)
Description
When VLOCK signal cannot be detected during the FG
of detection
rotation of polygon scanner (either the VLOCK signal cannot
be detected within 7.5 sec from startup or VLOCK signal
cannot be detected for 1 sec continuously after the VLOCK
signal is detected once.).
"x" in the detailed code represents the numeric values.
Occurrence timing can be identified by this numeric values (for
design review). As a field remedy, laser scanner needs to be
replaced regardless of this numeric values.
Measures
1. Check the connector.
2. Replace the laser scanner unit.
3. Replace the DC controller PCB.
E110 0012
05
Title
Error in scanner motor (BD detection fails.)
Description
When VLOCK signal cannot be detected during the FG
of detection
rotation of polygon scanner (either the VLOCK signal cannot
be detected within 7.5 sec from startup or VLOCK signal
cannot be detected for 1 sec continuously after the VLOCK
signal is detected once.).
"x" in the detailed code represents the numeric values.
Occurrence timing can be identified by this numeric values (for
design review). As a field remedy, laser scanner needs to be
replaced regardless of this numeric values.
Measures
1. Check the connector.
2. Replace the laser scanner unit.
3. Replace the DC controller PCB.
7
Error Code > Error Code > Error Code Details
Description
7
Error Code > Error Code > Error Code Details
Detail
Code
Location
Item
Code
E110 0013
05
Title
Error in scanner motor (Detection fails after BD detection.)
Description
When VLOCK signal cannot be detected during the FG
of detection
rotation of polygon scanner (either the VLOCK signal cannot
be detected within 7.5 sec from startup or VLOCK signal
cannot be detected for 1 sec continuously after the VLOCK
signal is detected once.).
"x" in the detailed code represents the numeric values.
Occurrence timing can be identified by this numeric values (for
design review). As a field remedy, laser scanner needs to be
replaced regardless of this numeric values.
Measures
1. Check the connector.
2. Replace the laser scanner unit.
3. Replace the DC controller PCB.
E110 0015
05
Title
Error in scanner motor (Rotation accuracy error during phase
control)
Description
When VLOCK signal cannot be detected during the FG
of detection
rotation of polygon scanner (either the VLOCK signal cannot
be detected within 7.5 sec from startup or VLOCK signal
cannot be detected for 1 sec continuously after the VLOCK
signal is detected once.).
"x" in the detailed code represents the numeric values.
Occurrence timing can be identified by this numeric values (for
design review). As a field remedy, laser scanner needs to be
replaced regardless of this numeric values.
Measures
1. Check the connector.
2. Replace the laser scanner unit.
3. Replace the DC controller PCB.
E110 0016
05
Title
Error in scanner motor (Error after phase lock)
Description
When VLOCK signal cannot be detected during the FG
of detection
rotation of polygon scanner (either the VLOCK signal cannot
be detected within 7.5 sec from startup or VLOCK signal
cannot be detected for 1 sec continuously after the VLOCK
signal is detected once.).
"x" in the detailed code represents the numeric values.
Occurrence timing can be identified by this numeric values (for
design review). As a field remedy, laser scanner needs to be
replaced regardless of this numeric values.
Measures
1. Check the connector.
2. Replace the laser scanner unit.
3. Replace the DC controller PCB.