Technology > Fixing System > Overview > Basic Sequence
■ Basic Sequence
● Power-ON
Power On
WMUP1
Fixing roller:
Target temperature
180 degree C
Main heater(H2)
Fixing roller
Sub heater(H3)
Main heater(H8)
Pressure roller
Sub heater(H9)
Main heater(H4)
External heat
upper roller
Sub heater(H5)
Main heater(H6)
External heat
lower roller
Sub heater(H7)
Pressure roller motor(M10)
External heat engage/disnage
motor(M12)
Fixing main motor(M11)
Name of the Interval
The interval from when the power is turned on to when the temperature of
Warm-up 1
the fixing roller surface reaches 180 degree C.
After the temperature is reached, the machine moves to Warm-up 2.
The interval until the temperature of the fixing roller surface reaches 205
Warm-up 2
degree C.
Warm-
After the temperature is reached, the machine moves to Warm-up 3.
up
he interval until the temperature of the fixing roller surface reaches 210
degree C
Warm-up 3
Pressure roller: 150 degree C
External heat roller 1, 2: 230 degree C
After the temperature is reached, the machine moves to Standby.
The status where a print request signal can be received
• Fixing roller: 210 degree C
• Pressure roller: 150 degree C
Standby
• External heating roller 1, 2: 230 degree C
* Temperature of the fixing roller main thermistor
• 210 degree C or higher: 200 degree C control
• Lower than 210 degree C: 210 degree C control
2
Technology > Fixing System > Overview > Basic Sequence
WMUP2
WMUP3
STBY
Fixing roller:
Fixing roller:210 degree C
205 degree C
Pressure roller:150 degree C
External heat upper/lower roller:230 degree C
Engage
Disengage
Engage
Disengage
Difinition
T-2-59
● Print (A4, Normal mode)
Main heater (H2)
Fixing roller
Sub heater (H3)
Main heater (H8)
Pressure roller
Sub heater (H9)
Sub heater (H4)
External heat
upper roller
Sub heater (H5)
Main heater (H6)
External heat
lower roller
Sub heater (H7)
Pressure roller pressure
motor (M10)
Extermnal heat
engage/disengage motor (M12)
Fixing main motor (M11)
Name of the
F-2-91
Interval
The interval from when a print request signal is received to when an image
Initial Rotation
signal is sent.
The interval from when image formation starts to when paper is delivered.
Different temperature control table and lighting heater are used depending
on the paper size, paper type, and temperature of the edge of the fixing
roller.
Print
Transmission sequence differs depending on the edge temperature of the
pressure roller at print end.
• Below 180 deg C: transferred to the post rotation
• 180 deg C or higher: transferred to post-rotation 1 -> post rotation 2
After 5 sec from when the paper goes through the fixing nip, the pressure
Last Rotation
roller/external heat roller is disengaged and it stops.
The fans cool down the pressure roller.
If the edge temperature of the pressure roller drops by 10 deg C from the
Last Rotation 1
entry temperature (180 deg C or higher), the machine goes to the post-
rotation 2.
The fans cool down the pressure roller.
Last Rotation 2
If the edge temperature of the pressure roller drops below 165 deg C, the
machine goes to standby mode.
STBY
INTR
PRINT
Engage
Engage
Difinition
2-67
LSTR
STBY
Disengage
Disengage
F-2-92