■ MISC
COPIER> DISPLAY> MISC
ENV-TR
Display of device inside environment
Lv.1 Details
Displaying environment in the device in the latest output.
Use case
When checking the current installation environment of the host
machine.
Adj/set/operate method Select the item
Display/adjust/set range 0 to 7
LPOWER
Display of laser light intensity
Lv.2 Details
Displaying the laser power setting value during image formation in
the real time
To check if the laser power is different between the coated paper and
the plain paper.
Use case
In the case of image fault
Adj/set/operate method Select the item
Display/adjust/set range 0 to 255
ENV-TR2
Dspl of environment at sec transfer ATVC
Lv.2 Details
Displaying environment at the time of latest execution of the
secondary transfer ATVC control.
Use case
When checking the current installation environment of the host
machine.
Adj/set/operate method Select the item
Display/adjust/set range 0 to 7
Related service mode
COPIER> DISPLAY> MISC> ENV-TR
DEV-SP1
Device special setting 1: For R&D
DEV-SP2
Device special setting 2: For R&D
DEV-SP3
Device special setting 3: For R&D
DEV-SP4
Device special setting 4: For R&D
DEV-SP5
Device special setting 5: For R&D
DEV-SP6
Device special setting 6: For R&D
DEV-SP7
Device special setting 7: For R&D
DEV-SP8
Device special setting 8: For R&D
8
Service Mode > COPIER > DISPLAY (Status Display Mode) > ENVRNT
T-8-13
8
Service Mode > COPIER > DISPLAY (Status Display Mode) > ENVRNT
■ ENVRNT
COPIER> DISPLAY> ENVRNT
001
Dspl of environment log data No.1
Lv.1
Details
Displaying the environment log data (inside temperature,
humidity, fixing roller temperature) No.1.
The machine saves the inside temperature(deg C), humidity(%)
and fixing roller temperature(deg C) that are calculated from
the detected results of environment sensor and the fixing main
thermistor as log data per 60 min.
Latest 13 logs are saved and when a new data is collected, the
earliest data will be deleted.
Use case
When checking the inside environment of the host machine.
Adj/set/operate method
Select the item
002
Dspl of environment log data No.2
Lv.1
Details
Displaying the environment log data (inside temperature,
humidity, fixing roller temperature) No.2.
The machine saves the inside temperature(deg C), humidity(%)
and fixing roller temperature(deg C) that are calculated from
the detected results of environment sensor and the fixing main
thermistor as log data per 60 min.
Latest 13 logs are saved and when a new data is collected, the
earliest data will be deleted.
Use case
When checking the inside environment of the host machine.
Adj/set/operate method
Select the item
003
Dspl of environment log data No.3
Lv.1
Details
Displaying the environment log data (inside temperature,
humidity, fixing roller temperature) No.3.
The machine saves the inside temperature(deg C), humidity(%)
and fixing roller temperature(deg C) that are calculated from
the detected results of environment sensor and the fixing main
thermistor as log data per 60 min.
Latest 13 logs are saved and when a new data is collected, the
earliest data will be deleted.
Use case
When checking the inside environment of the host machine.
Adj/set/operate method
Select the item
004
Dspl of environment log data No.4
Lv.1
Details
Displaying the environment log data (inside temperature,
humidity, fixing roller temperature) No.4.
The machine saves the inside temperature(deg C), humidity(%)
and fixing roller temperature(deg C) that are calculated from
the detected results of environment sensor and the fixing main
thermistor as log data per 60 min.
Latest 13 logs are saved and when a new data is collected, the
earliest data will be deleted.
Use case
When checking the inside environment of the host machine.
Adj/set/operate method
Select the item
8-38