Code
Location
Item
Code
E501 0005
51
Title
Communication error with the stacker
Description
NACK reception
of detection
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0005
52
Title
Communication error with the 2nd stacker
Description
NACK reception
of detection
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0006
51
Title
Communication error with the stacker
Description
Error reception by parallel signal from the option controller
of detection
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0006
52
Title
Communication error with the 2nd stacker
Description
Error reception due to parallel signal from the option controller
of detection
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0011
51
Title
Communication error with the stacker
Description
Communication error was notified with parallel signal because
of detection
the stacker detects communication error
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
7
Error Code > Error Code > Error Code Details
Description
7
Error Code > Error Code > Error Code Details
Detail
Code
Location
Item
Code
E501 0011
52
Title
Communication error with the 2nd stacker
Description
Communication error was notified with parallel signal because
of detection
the stacker detects communication error
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0012
51
Title
Communication error with the stacker
Description
There was an overrun error, parity error, or flaming error while
of detection
receiving 1-byte data
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0012
52
Title
Communication error with the 2nd stacker
Description
There was an overrun error, parity error, or flaming error while
of detection
receiving 1-byte data
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0013
51
Title
Communication error with the stacker
Description
Transmission process is not completed despite 5-time
of detection
transmission retry
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0013
52
Title
Communication error with the 2nd stacker
Description
Transmission process is not completed despite 5-time
of detection
transmission retry
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.