Canon imagePRESS 1135 Series Service Manual page 968

Hide thumbs Also See for imagePRESS 1135 Series:
Table of Contents

Advertisement

COPIER> DISPLAY> ANALOG
MI1-TEMP
Temperature of multi inserter storage
Lv.1 Details
Displaying temperature in the deck of the multi insertion unit.
Measured by the environment sensor that detects the deck.
Use case
When checking temperature in the deck.
Adj/set/operate method N/A (display only)
Unit
Degree C
Appropriate target value 20 to 27
Related service mode
COPIER> DISPLAY> ANALOG> DK1-TEMP, DK2-TEMP, DK3-
TEMP
DK3-TEMP
Dspl of inside temperature of POD deck3
Lv.1 Details
Displaying temperature inside the 2nd secondary POD deck storage.
Measured by the environment sensor (HS601) found at the upper
deck.
Use case
When checking the temperature inside the storage.
Adj/set/operate method N/A (display only)
Unit
Degree C
Appropriate target value 20 to 27
Related service mode
COPIER> DISPLAY> ANALOG> DK1-TEMP, DK2-TEMP
DK3-HUM
Dspl of inside humidity of POD deck3
Lv.1 Details
Displaying humidity inside the 2nd secondary POD deck storage.
Measured by the environment sensor (HS601) found at the upper
deck.
Use case
When checking the humidity inside the storage.
Adj/set/operate method N/A (display only)
Unit
%
Appropriate target value 30 to 70
Related service mode
COPIER> DISPLAY> ANALOG> DK1-HUM, DK2-HUM
8
Service Mode > COPIER > DISPLAY (Status Display Mode) > ANALOG
T-8-6
8
Service Mode > COPIER > DISPLAY (Status Display Mode) > ANALOG
8-25
8-25