Parts Replacement and Cleaning > Main Unit > Pulling Out ITB Unit
2) Remove the ITB positioning plate with the 2 screws.
Caution :
• When pulling out the ITB unit from the host machine, be sure to also pull out the fixing feed unit at the same time, otherwise it might scratch the intermediate transfer belt.
• Be sure to pull out the Fixing Feed Unit and ITB Unit to the position where latch is locked.
Reason: Disengagement between the Positioning Pin of the Secondary Transfer Outer Unit and Shaft Support Member of the frame body of the ITB Unit becomes
insufficient, and it may cause damage when assembling the Intermediate Transfer Belt Unit.
3) Turn the fixing feed unit lever in the direction of the arrow.
4) Hold the fixing feed unit lever, and fully pull out the fixing feed unit to the front side.
4
Parts Replacement and Cleaning > Main Unit > Pulling Out ITB Unit