4
Parts Replacement and Cleaning > Main Unit > Removing Fixing Pressure Unit
• When making the cam from the standing status [A] to the lying status [B].
Caution :
Be sure that the screw of the cam is in the correct direction when making the cam in a lying state. If the direction is incorrect, the cam may not rotate normally.
Caution : Caution during fixing pressure unit installation
Adjust the fixing pressure unit pressure shaft to the
hole of the external heat roller unit, and install the fixing
pressure unit with the 2 screws.
4
Parts Replacement and Cleaning > Main Unit > Removing Fixing Pressure Unit
[A] Pressing status
加圧状態
Gear
Pressure Shaft
Hole
Screw
[B] Released status
解除状態
Hole
Cam
Cam
Screw
4-109
Screw
Cam
Hole
Screw
Screw
F-4-162
Hole
Pressure Shaft
Screw
Fixing pressure unit
F-4-163