Canon imagePRESS 1135 Series Service Manual page 1002

Hide thumbs Also See for imagePRESS 1135 Series:
Table of Contents

Advertisement

Address
bit
Name
P061
15
Not use
14
Not use
13
Lower deck air heater unit Connect
Detection
12
Middle deck air heater unit Connect
Detection
11
Upper deck air heater unit Connect
Detection
10
Cassette heater (lower deck) Connect
Detection
9
Cassette heater (middle deck) Connect
Detection
8
Not use
7
Not use
6
Not use
5
Not use
4
Middle deck safety switch
3
Air heater unit ERR
2
Air heater unit ready
1
Middle deck right flotation fan ERR
0
Middle deck left flotation fan ERR
P062
15
Lower deck safety switch
14
Middle deck safety switch
13
Upper deck safety switch
12
Not use
11
Not use
10
Power supply cooling fan error
9
Deck left front cover open/close sensor
8
Deck left front cover safety switch
7
Double feed Detection Signal
6
Double feeding sensor (receive)
connection check
5
Double feeding sensor (transmission)
connection check
4
Lower deck safety switch
3
Air heater unit ERR
2
Air heater unit ready
1
Lower deck right flotation fan ERR
0
Lower deck left flotation fan ERR
8
Service Mode > COPIER > I / O > Side Paper Deck-AF1 (Multi Drawer) (DCON > P053 to P064)
Symbol
Remarks
-
-
-
-
HT301
0: Installed, 1: Not
installed
HT201
0: Installed, 1: Not
installed
HT101
0: Installed, 1: Not
installed
CHT301
-
CHT201
-
-
-
-
-
-
-
-
-
S208
1: Open, 0: Close
HT201
0: High Temperature
1: Normal Temperature
HT201
0: Low Temperature
1: Blast temperature
FAN202
0: Error
FAN201
0: Error
S308
1: ON
S208
1: ON
S108
1: ON
-
-
-
0: Error
FAN001
0: Error
S006
1: Close, 0: Open
S007
1: +24V 4Energization
Detection, 0: Door close,
Energization;0
0: Double feed
S009
GND Detection, Connect
: 0
S010
GND Detection, Connect
: 0
S308
1: Open, 0: Close
HT301
0: High Temperature
1: Normal Temperature
HT301
0: Low Temperature
1: Blast temperature
FAN302
0: Error
FAN301
0: Error
8
Service Mode > COPIER > I / O > Side Paper Deck-AF1 (Multi Drawer) (DCON > P053 to P064)
Address
bit
Name
P063
15
Lower deck right flotation fan EN
14
Lower deck left flotation fan EN
13
Air heater unit ON/OFF SEL
12
Air heater unit ON
11
Air heater unit BIT1
10
Air heater unit BIT0
9
Lower deck swing motor DIR
8
Lower deck swing motor EN
7
Vertical path lower feed mode
6
Vertical path lower feed CWB
5
Right flotation fan BIT1
4
Right flotation fan BIT0
3
Not use
2
Left flotation fan BIT1
1
Left flotation fan BIT0
0
Vertical path upper feed EN
P064
15
AD HUM/TMP switch
14
+24V3 ON
13
Lower deck LED
12
Lower deck open/close solenoid
11
Lower deck pull-out clutch
10
Lower deck pickup clutch
9
Lower deck lifter motor CWB
8
Lower deck lifter motor EN
7
Deck pickup motor EN
6
+24V1 ON
5
Upper deck LED
4
Upper deck open/close solenoid
3
Upper deck pull-out clutch
2
Upper deck pickup clutch
1
Upper deck lifter motor CWB
0
Upper deck lifter motor EN
8-59
Symbol
Remarks
FAN302
1: ON
FAN301
1: ON
HT301
1: +5V A1T3 ON
HT301
1: ON
HT301
1: Select BIT1
HT301
1: Select BIT0
M302
1: CW, 0: CCW
M302
1: ON
-
1: 1-2 phase both edges,
0: W1-2 phase both
edges
-
0: CCW, 1: CW
FAN102,
1: Select BIT1
FAN202,
FAN302
FAN102,
1: Select BIT0
FAN202,
FAN302
1: Select BIT2
FAN101,
1: Select BIT1
FAN201,
FAN301
FAN101,
1: Select BIT0
FAN201,
FAN301
-
0: ON
-
1: Humidity, 0:
Temperature
-
1: +24V3 ON
-
1: ON
SL302
0: Deck open
CL302
1: Connect
CL301
1: Connect
M301
1: CW, 0: CCW
M301
0: ON
M001
1: ON
-
1: 24V1 ON
-
1: ON
SL102
0: deck open
CL102
1: Connect
CL101
1: Connect
M101
1: CW,0: CCW
M101
0: ON
8-59

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents