Canon imagePRESS 1135 Series Service Manual page 970

Hide thumbs Also See for imagePRESS 1135 Series:
Table of Contents

Advertisement

COPIER> DISPLAY> HV-STS
2TR-I
Dspl of sec transfer application current
Lv.2 Details
Displaying the current (target value) that is applied in the latest to the
secondary transfer inner roller.
Checking of the voltage at this time is available with 2TR-V.
Use case
When checking the setting value of the applied current.
Adj/set/operate method N/A (display only)
Display/adjust/set range -200 to 0
Unit
uA
Appropriate target value -55
Default value
-55
Related service mode
COPIER> ADJUST> HV-TR> 2TR-TGT1 to 2TR-TGT8
COPIER> DISPLAY> HV-STS> 2TR-V
2TR-PPR
Dspl sec transfer paper alloted voltage
Lv.2 Details
Displaying the latest paper-allotted voltage.
Paper-allotted voltage is the correction voltage to be applied at the
time of secondary transfer according to the paper type, environment
or paper-feeding side.
Use case
When checking the latest paper-allotted voltage.
Adj/set/operate method N.A. (display only)
Display/adjust/set range Paper type: 1 to 8 (1: Plain1 (63 g/m2 or less), 2: Plain2 (64 to 79 g/
m2), 3: Plain3 (80 to 105 g/m2), 4: Plain4 (106 to 128 g/m2), 5: Thick
1 (129 to 150 g/m2), 6: Thick 2 (151 to 209 g/m2), 7: Thick3 (210 to
256 g/m2), 8: Thick4 (257 g/m2 or more))
Alloted vlotage: -7000 to 0
Unit
Paper type: N.A., paper type: N.A., allotted voltage: V
Appropriate target value Paper type: N.A., Allotted voltage: -7000 to -300
Related service mode
COPIER> ADJUST> HV-TR> 2TR-SHR1 to 2TR-SHR8
COPIER> DISPLAY> HV-STS> 2TR-V
2TR-BASE
Dspl of base voltage of sec transfer
Lv.2 Details
Displaying base voltage when a specified amount of current is
applied to the secondary transfer inner roller.
To be derived from the result of the latest ATVC control.
Equivalent to the difference between the applied voltage and the
allotted voltage.
Use case
When checking the result of the secondary transfer ATVC control
Adj/set/operate method N/A (display only)
Display/adjust/set range -7000 to 0
Unit
V
Appropriate target value -7000 to -300
Related service mode
COPIER> DISPLAY> HV-STS> 2TR-V, 2TR-PPR
8
Service Mode > COPIER > DISPLAY (Status Display Mode) > HV-STS
8
Service Mode > COPIER > DISPLAY (Status Display Mode) > HV-STS
COPIER> DISPLAY> HV-STS
2TR-CLNV
Dspl sec transfer cleaning bias voltage
Lv.2 Details
To display the secondary transfer cleaning bias voltage value that is
lastly applied to the secondary transfer inner roller.
Secondary transfer cleaning bias voltage is calculated from the result
of ATVC control.
The current at this time can be checked by 2TR-CLNI
Use case
For checking when paper back soil occurs.
Adj/set/operate method N/A (display only)
Display/adjust/set range 0 to 3000
Unit
V
Appropriate target value 300 to 3000
Related service mode
COPIER> DISPLAY> HV-STS> 2TR-CLNI
2TR-CLNI
Dspl sec transfer cleaning bias current
Lv.2 Details
To display the secondary transfer cleaning bias current (target value)
that is lastly applied to the secondary transfer inner roller.
The voltage at this time can be checked by 2TR-CLNV
Use case
For checking when paper back soil occurs.
Adj/set/operate method N/A (display only)
Display/adjust/set range 0 to 100
Unit
uA
Appropriate target value 55
Default value
55
Related service mode
COPIER> ADJUST> HV-TR> 2TR-CLOF
COPIER> DISPLAY> HV-STS> 2TR-CLNV
8-27
T-8-7
8-27

Hide quick links: