Detail
Code
Location
Item
Code
E003 0006
05
Title
Error in low temperature detection
Description
Error in low temperature detection of external heat upper
of detection
roller. (Detected temperature of sub thermistor on the external
heat upper roller is 60 deg C or lower against the target for 1
sec.)
Measures
1. Clean the external heat upper roller sub thermistor.*
2. Replace the external heat roller thermistor.*
3. Replace the external heat heater 1.*
4. Replace the fixing heater control PCB.
*: When the counter value of the external heat upper roller is
less than 1,000,000. Replace the external heat roller unit in
the case of 1,000,000 or more.
E003 0007
05
Title
Error in low temperature detection
Description
Error in low temperature detection of external heat lower
of detection
roller. (Detected temperature of main thermistor on the
external heat lower roller is 60 deg C or lower against the
target for 1 sec.)
Measures
1. Clean the external heat lower roller main thermistor.*
2. Replace the external heat roller thermistor.*
3. Replace the external heat heater 2.*
4. Replace the fixing heater control PCB.
*: When the counter value of the external heat lower roller is
less than 1,000,000. Replace the external heat roller unit in
the case of 1,000,000 or more.
E003 0008
05
Title
Error in low temperature detection
Description
Error in low temperature detection of external heat lower
of detection
roller. (Detected temperature of sub thermistor on the external
heat lower roller is 60 deg C or lower against the target for 1
sec.)
Measures
1. Clean the external heat lower roller sub thermistor.*
2. Replace the external heat roller thermistor.*
3. Replace the external heat heater 2.*
4. Replace the fixing heater control PCB.
*: When the counter value of the external heat lower roller is
less than 1,000,000. Replace the external heat roller unit in
the case of 1,000,000 or more.
E003 9999
05
Title
Error in low temperature detection
Description
Before an error is detected by other low temperature
of detection
detection error, the relay was turned OFF by the hardware
detection.
Measures
This error does not usually occur because software detection
is performed before hardware detection.
7
Error Code > Error Code > Error Code Details
Description
7
Error Code > Error Code > Error Code Details
Detail
Code
Location
Item
Code
E004 0011
05
Title
Heater ON/OFF detection circuit error
Description
ON/OFF detection circuit error of the fixing heater (main)
of detection
Measures
1. Check the fixing heater connector.
2. Replace the fixing heater.
3. Replace the fixing heater control PCB.
E004 0012
05
Title
Heater ON/OFF detection circuit error
Description
ON/OFF detection circuit error of the fixing heater (sub)
of detection
Measures
1. Check the fixing heater connector.
2. Replace the fixing heater.
3. Replace the fixing heater control PCB.
E004 0013
05
Title
Heater ON/OFF detection circuit error
Description
ON/OFF detection circuit error of the pressure roller heater
of detection
(main)
Measures
1. Check the pressure roller heater connector.
2. Replace the pressure roller heater.
3. Replace the fixing heater control PCB.
E004 0014
05
Title
Heater ON/OFF detection circuit error
Description
ON/OFF detection circuit error of the external heat heater 1
of detection
(main)
Measures
1. Check the external heat heater 1 connector.
2. Replace the external heat heater 1.*
3. Replace the fixing heater control PCB.
*: When the counter value of the external heat upper roller is
less than 1,000,000. Replace the external heat roller unit in
the case of 1,000,000 or more.
E004 0015
05
Title
Heater ON/OFF detection circuit error
Description
ON/OFF detection circuit error of the external heat heater 2
of detection
(main)
Measures
1. Check the external heat heater 2 connector.
2. Replace the external heat heater 2.*
3. Replace the fixing heater control PCB.
*: When the counter value of the external heat lower roller is
less than 1,000,000. Replace the external heat roller unit in
the case of 1,000,000 or more.
E004 0016
05
Title
Heater ON/OFF detection circuit error
Description
ON/OFF detection circuit error of the external heat heater 1
of detection
(sub)
Measures
1. Check the external heat heater 1 connector.
2. Replace the external heat heater 1.*
3. Replace the fixing heater control PCB.
*: When the counter value of the external heat upper roller is
less than 1,000,000. Replace the external heat roller unit in
the case of 1,000,000 or more.
7-8
Description
7-8