Parts Replacement and Cleaning > Periodic Replacing Parts, Durable Parts, Cleaning Parts > Installing the ITB cleaning blade > When replacing the blade with a new one
Installing the ITB cleaning blade
■ When replacing the blade with a new one
1) Check that the surface side of the blade to be installed is facing upward (judge it by the stamp of the lot No.).
<Blade with its surface side facing upward.>
<Blade with its surface side facing downward.>
2) When installing the cleaning blade, align the both sides [A] of cleaning cover with the both sides [B]
of cleaning blade, and push it to rear [C] part to install.
[C] part
[A]
[B]
4
Parts Replacement and Cleaning > Periodic Replacing Parts, Durable Parts, Cleaning Parts > Installing the ITB cleaning blade > When replacing the blade with a new one
F-4-487
3) When tightening the screw, hold the cleaning blade and temporary tighten it in the following
procedure.
[A]
[B]
F-4-488
CAUTION:
• If the surface and back sides are mistaken, image failure may
occur due to toner slipping.
• Be sure to install the blade with its surface side facing