Canon imagePRESS 1135 Series Service Manual page 765

Hide thumbs Also See for imagePRESS 1135 Series:
Table of Contents

Advertisement

Detail
Code
Location
Item
Code
E500 00A5
71
Title
Error due to unexpected operation
Description
-
of detection
Measures
If an error cannot be released by turning OFF/ON the power,
contact a sales company.
E500 00D4
02
Title
Error due to unexpected operation
Description
-
of detection
Measures
If an error cannot be released by turning OFF/ON the power,
contact a sales company.
E501 0001
51
Title
Communication error with the stacker
Description
SCI Communication error (parity, flaming, overrun)
of detection
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0001
52
Title
Communication error with the 2nd stacker
Description
SCI communication error (parity, flaming, overrun)
of detection
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0001
71
Title
Communication error with insertion unit
Description
Serial communication error between the inserter control PCB
of detection
and the option controller PCB
Measures
1. Check the connector of the inserter control PCB.
2. Check the connector of the option controller PCB.
3. Check the connection of the communication cable.
4. Replace the inserter control PCB.
5. Replace the option controller PCB.
6. Replace the communication cable.
E501 0002
51
Title
Communication error with the stacker
Description
Abnormal data reception (mismatched checksum/EXT
of detection
abnormal data reception)
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
7
Error Code > Error Code > Error Code Details
Description
7
Error Code > Error Code > Error Code Details
Detail
Code
Location
Item
Code
E501 0002
52
Title
Communication error with the 2nd stacker
Description
Abnormal data reception (mismatched checksum/EXT
of detection
abnormal data reception)
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0003
51
Title
Communication error with the stacker
Description
Reception timeout
of detection
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0003
52
Title
Communication error with the 2nd stacker
Description
Reception timeout
of detection
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0004
51
Title
Communication error with the stacker
Description
Unreceived ACK (transmission timeout)
of detection
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
E501 0004
52
Title
Communication error with the 2nd stacker
Description
Unreceived ACK (transmission timeout)
of detection
Measures
1. Check the connector of the option controller PCB.
2. Check the connector of the master controller PCB.
3. Check the connection of the harness between the master
controller PCB and the option controller PCB.
4. Replace the option controller PCB.
5. Replace the master controller PCB.
7-33