Canon imagePRESS 1135 Series Service Manual page 764

Hide thumbs Also See for imagePRESS 1135 Series:
Table of Contents

Advertisement

Detail
Code
Location
Item
Code
E500 0001
52
Title
Error in ARCNET communication
Description
Communication failed between the host machine and the
of detection
High Capacity Stacker.
Measures
1. Check the power of the option.
2. Check the connection of the ARCNET cable.
3. Replace the ARCNET driver PCB.
4. Replace the option controller PCB.
* If any of those is not assumed as a cause, this error might
have occurred on another option.
E500 0001
61
Title
Error in ARCNET communication
Description
Communication failed between the host machine and the
of detection
Perfect Binder.
Measures
1. Check the power of the option.
2. Check the connection of the ARCNET cable.
3. Replace the ARCNET driver PCB.
4. Replace the option controller PCB.
* If any of those is not assumed as a cause, this error might
have occurred on another option.
E500 0001
71
Title
Error in ARCNET communication
Description
Communication failed between the host machine and the
of detection
Document Insertion Unit.
Measures
1. Check the connector of the inserter control PCB/option
controller PCB.
2. Check the connection of the communication cable.
3. Check the connector of the communication driver PCB.
4. Replace the inserter control PCB/option controller PCB.
5. Replace the communication cable.
6. Replace the communication driver PCB.
* If any of those is not assumed as a cause, this error might
have occurred on another option.
E500 0022
02
Title
Error due to unexpected operation
Description
-
of detection
Measures
If an error cannot be released by turning OFF/ON the power,
contact a sales company.
E500 0098
02
Title
Error due to unexpected operation
Description
-
of detection
Measures
If an error cannot be released by turning OFF/ON the power,
contact a sales company.
E500 0099
02
Title
Error due to unexpected operation
Description
-
of detection
Measures
If an error cannot be released by turning OFF/ON the power,
contact a sales company.
7
Error Code > Error Code > Error Code Details
Description
7
Error Code > Error Code > Error Code Details
Detail
Code
Location
Item
Code
E500 00A1
51
Title
Error due to unexpected operation
Description
-
of detection
Measures
If an error cannot be released by turning OFF/ON the power,
contact a sales company.
E500 00A2
51
Title
Error due to unexpected operation
Description
-
of detection
Measures
If an error cannot be released by turning OFF/ON the power,
contact a sales company.
E500 00A3
51
Title
Error due to unexpected operation
Description
-
of detection
Measures
If an error cannot be released by turning OFF/ON the power,
contact a sales company.
E500 00A4
51
Title
Error due to unexpected operation
Description
-
of detection
Measures
If an error cannot be released by turning OFF/ON the power,
contact a sales company.
E500 00A5
51
Title
Error due to unexpected operation
Description
-
of detection
Measures
If an error cannot be released by turning OFF/ON the power,
contact a sales company.
E500 00A1
71
Title
Error due to unexpected operation
Description
-
of detection
Measures
If an error cannot be released by turning OFF/ON the power,
contact a sales company.
E500 00A2
71
Title
Error due to unexpected operation
Description
-
of detection
Measures
If an error cannot be released by turning OFF/ON the power,
contact a sales company.
E500 00A3
71
Title
Error due to unexpected operation
Description
-
of detection
Measures
If an error cannot be released by turning OFF/ON the power,
contact a sales company.
E500 00A4
71
Title
Error due to unexpected operation
Description
-
of detection
Measures
If an error cannot be released by turning OFF/ON the power,
contact a sales company.
7-32