Advertisement

Detail
Code
Location
Item
Code
E315 0520
00
Title
Error in device timeout
Description
If interruption does not occur within 2 min from start-up.
of detection
Measures
1. DDI-S (Check RCON and I/F)
2. Replace the main controller PCB.
E315 0521
00
Title
Error in device abnormal termination
Description
When an abnormal interruption is detected after startup.
of detection
Measures
1. DDI-S (Check RCON and I/F)
2. Replace the main controller PCB.
E315 0530
00
Title
Error in device timeout
Description
If interruption does not occur within 2 min from start-up.
of detection
Measures
1. Turn OFF/ON.
2. If symptom occurs frequently, replace the main controller
PCB.
E315 0531
00
Title
Error in device abnormal termination
Description
When an abnormal interruption is detected after startup.
of detection
Measures
1. Turn OFF/ON.
2. If symptom occurs frequently, replace the main controller
PCB.
E315 0540
00
Title
Error in device timeout
Description
If interruption does not occur within 2 min from start-up.
of detection
Measures
1. Turn OFF/ON.
2. If symptom occurs frequently, replace the main controller
PCB.
E315 0541
00
Title
Error in device abnormal termination
Description
When an abnormal interruption is detected after startup.
of detection
Measures
1. Turn OFF/ON.
2. If symptom occurs frequently, replace the main controller
PCB.
E315 0550
00
Title
Error in device timeout
Description
If interruption does not occur within 2 min from start-up.
of detection
Measures
1. DDI-S (Check RCON and I/F)
2. Replace the main controller PCB.
E315 0551
00
Title
Error in device abnormal termination
Description
When an abnormal interruption is detected after startup.
of detection
Measures
1. DDI-S (Check RCON and I/F)
2. Replace the main controller PCB.
7
Error Code > Error Code > Error Code Details
Description
7
Error Code > Error Code > Error Code Details
Detail
Code
Location
Item
Code
E315 0560
00
Title
Error in device timeout
Description
If interruption does not occur within 2 min from start-up.
of detection
Measures
1. DDI-S (Check RCON and I/F)
2. Replace the main controller PCB.
E315 0561
00
Title
Error in device abnormal termination
Description
When an abnormal interruption is detected after startup.
of detection
Measures
1. DDI-S (Check RCON and I/F)
2. Replace the main controller PCB.
E350 0000
00
Title
ECO-ID PCB-related error
Description
of detection
Measures
Contact a sales company.
E350 0001
00
Title
ECO-ID PCB-related error
Description
of detection
Measures
Contact a sales company.
E350 0002
00
Title
ECO-ID PCB-related error
Description
of detection
Measures
Contact a sales company.
E350 0003
00
Title
ECO-ID PCB-related error
Description
of detection
Measures
Contact a sales company.
E350 3000
00
Title
ECO-ID PCB-related error
Description
of detection
Measures
Contact a sales company.
E351 0000
00
Title
ECO-ID PCB-related error
Description
of detection
Measures
Contact a sales company.
E354 0001
00
Title
ECO-ID PCB-related error
Description
of detection
Measures
Contact a sales company.
E354 0002
00
Title
ECO-ID PCB-related error
Description
of detection
Measures
Contact a sales company.