Image Logging; Logging Conditions (Image Logging) - Omron XPECTIA FZ3 User Manual

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

Image Logging

This is used when saving measurement images to on-board memory, RAMDisk or USB memory.
This enables preparation of logging conditions using an expression and is more flexible than the system
image logging conditions settings.
However, the settings of this unit are enabled if "None" is set on the [Logging setting] of the main screen
[Measure] menu.
If settings that perform image logging for multiple units during measurement are executed, the last
settings executed are enabled.
4
Used in the Following Case
This is used when saving logging images under specific conditions.
Important
If several image logging units are set in the flow, saving is performed based on the last image logging conditions
executed.

Logging Conditions (Image Logging)

Indicate the image to perform logging for.If 4 cameras are connected, image logging is performed for 4
cameras each time.
1.
Tap [Logging condition] in the Item Tab area.
2.
Set the logging conditions.
Setting item
Logging
condition
3.
When "Only NG" is selected, tap [...].
378
Image Logging
Set value
[Factory
default]
[None]
No images are saved.
Saves images only if an NG occurs.If an NG occurs downstream from
Only NG
the image logging processing unit, image logging is not performed.
Insert image logging as close to the end of the scene as possible
All
All measured images are saved.
Description
FZ3 Processing Items List Manual

Advertisement

Table of Contents
loading