Display/Output Value Hold (Hold) - Omron Z4LB V2 Instruction Manual

Parallel beam linear sensor
Table of Contents

Advertisement

Key Settings
The selected digit flashes.
4-2-4

Display/Output Value Hold (hold)

There are six methods to hold the display and output values. Se-
lect the best method for the application.
Display
Name
norml Normal
p h Peak hold
b h Bottom hold
s h Sample hold
pp h Peak-to-peak
hold
sp h Self-peak hold
sb h Self-bottom hold
42
Default setting: The hysteresis is set to 0.020 when the
measurement unit is V, to 00.050 when the measurement
unit is mm and the measurement width is 10 mm, and to
00.150 when the measurement unit is mm and the measure-
ment width is 30 mm.
Setting Range
Measured value
display unit
di
l
it
V
mm
00.050
Select the digit.
6 Press the SET Key.
The set value will be entered and the Sensor will return to
function selection mode.
7 Press the TEACH Key to return to RUN mode.
The result of measurement is always
displayed and output. The hold does not
work.
The maximum value while the timing input is
ON is displayed, output, and held.
The minimum value while the timing input is
ON is displayed, output, and held.
The current value when the timing input turns
ON is displayed, output, and held.
The difference between the maximum and
minimum values while timing input is ON is
displayed, output, and held.
The maximum value while the measured
value is equal to or greater than the trigger
level is displayed, output, and held.
The minimum value while the measured
value is equal to or less than the trigger level
is displayed, output, and held.
Measurement width of the Sensor
10 mm
0.002 to 0.800
0.005 to 2.000
00.050
Set the value.
Description
Section
4-2
30 mm
0.015 to 6.000
00.060
Page
50
51
52
53
54
55
56

Advertisement