Setting Measurement Conditions For Different Models: Changing Scenes - Omron F160 Operation Manual

Vision sensor
Hide thumbs Also See for F160:
Table of Contents

Advertisement

Changing Scenes and Scene Groups
IIf a Memory Card is not used, only Scene group 0 can be used.
Memory Card
(128 Mbytes)
4-2-1
Setting Measurement Conditions for Different Models:
Changing Scenes
72
Scene group 0 will be saved in the internal flash memory and scene groups 1
to 31 will be saved to the Memory Card.
Scene group 0
F160
Scene groups 1 to 31 can be used if a Memory Card is mounted.
Scene group 0
F160
Scene group 0:
Scene groups 1 to 31: Saved to Memory Card
Use the scene changing function to switch between different measurement
conditions for different measurement setups or measurement objects. Scene 0
will be displayed by default when the power is turned ON, however, the F160
also accommodates scenes 1 to 31. If a Memory Card is inserted and the
scene group function used, up to 1,024 scenes can be set.
The command for changing scenes or scene groups can be input from an
external device via a parallel or serial interface.
Scene 0
Scene 1
Scene 30
Scene 31
1
Scene 0
2
Scene 1
Scene group 31
Scene 30
Scene 31
1,024 scenes max.
Saved to internal flash memory
Section 4-2
Scene 0
Scene 1
Scene 30
Scene 31