Toshiba e-STUDIO206L Service Manual page 1290

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

Sub
05/08
Mode
Element
element
05
Adjustmen
Process
Transfer
Transfer cleaning bias
t mode
adjustment
05
Adjustmen
Process
Transfer
Transfer cleaning bias
t mode
adjustment
05
Adjustmen
Process
Transfer
Temperature/humidity
t mode
sensor
05
Adjustmen
Process
Process
Temperature/humidity
t mode
sensor
05
Adjustmen
Process
Charger
t mode
e-STUDIO207L/257/307/357/457/507
Item
Subitem
Code
2083
2084
2192
2194
2196
Sub-
Default
Acceptable
Details
code
value
value
Positive
Refer to
0~255
contents
Negative
41
0~255
Humidity display
50
0~100
Temperature display
25
0~50
Drum thermistor
25
0~100
temperature display
(K)
2
RAM
Contents
M
When the high-voltage transformer is replaced, the
transfer cleaning bias needs to be adjusted with this
code. The larger the setting value is, the higher the
value of the current (more positive) is. This causes a
reduction in the toner adhering to the transfer roller and
an improvement in the cleaning performance. Perform
this adjustment after the process units (cleaner and
developer unit) have been removed. When the high-
voltage transformer is replaced, adjusting with the
following codes needs to be performed in addition to
this adjustment.
05-2020, 05-2040, 05-2052, 05-2078
<Default value>
e-STUDIO207L/257/307: 63
e-STUDIO357/457/507: 96
M
When the high-voltage transformer is replaced, the
transfer cleaning bias needs to be adjusted with this
code. The larger the setting value is, the higher the
value of the current (more negative) is. This causes a
reduction in the toner adhering to the transfer roller and
an improvement in the cleaning performance. Perform
this adjustment after the process units (cleaner and
developer unit) have been removed. When the high-
voltage transformer is replaced, adjusting with the
following codes need to be performed in addition to this
adjustment.
05-2020, 05-2040, 05-2052, 05-2078
M
Displays the humidity value detected by
temperature/humidity sensor.
M
Displays the humidity value detected by
temperature/humidity sensor.
M
(Unit: °C)
Proc
Service
edure
UI
3
3
2
Yes
2
Yes
2
Yes

Hide quick links:

Advertisement

Table of Contents
loading