 BIOS messages
The following table lists the messages for MegaRAID WebBIOS displayed at system
startup.
Message
Cache data was lost due to an unexpected power-off
or reboot during a write operation, but the adapter
has recovered. This could be due to memory
problems, bad battery, or you may not have a
battery installed.
Memory/battery problems were detected. The
adapter has recovered, but cached data was lost.
Foreign configurations found on adapter.
FW package: xxxx
The battery hardware is missing or malfunctioning,
or the battery is unplugged. If you continue to boot
the system, the battery-backed cache will not
function. Please contact technical support for
assistance.
Press 'D' to disable this warning (if your controller
does not have a battery).
Some configured disks have been removed from
your system or are no longer accessible. Please
check your cables and also ensure that all disks are
present.
The following VDs have missing disks: X Y...
If you proceed (or load the configuration utility),
these VDs will be marked OFFLINE and will be
inaccessible. Please check your cables and ensure
that all disks are present.
The following VDs are missing: X Y ...
If you proceed (or load the configuration utility),
these VDs will be removed from your configuration.
If you wish to use them at a later time, they will have
to be imported. If you believe these VDs should be
present, please power off your system and check
your cables to ensure all disks are present.
Description
An incorrect power-off or reboot has been
executed during write, parity check, rebuilding,
patrol read, or initializing operation.
There may be a cache memory failure, if this
event is registered at the reboot after the
system hangs in operation or if the OS cannot
boot up.
An unexpected power-off or reboot has been
executed during write, parity check, rebuilding,
patrol read or initializing operation.
There may be a cache memory failure, if this
event is registered at the reboot after the
system hangs in operation or if the OS cannot
boot up. *3
A hard disk with a different configuration from
the disk array configuration in the disk array
controller was detected.
See
Disk with a foreign
This shows the firmware package version. You
do not need to take any action.
Battery backup unit information is not set
correctly.
Press the 'D' key while this message is
displayed.
If not recovered, contact your reseller from
which you purchased the product or consult
maintenance personnel.
Some hard disks with the disk array
configuration information have been removed.
When this message is displayed even if the
device is installed properly, contact your reseller
from which you purchased the product or
consult maintenance personnel.
Since some hard disks have been removed, the
disk array is set in OFF LINE.
When this message is displayed even if the
device is installed properly, contact your reseller
from which you purchased the product or
consult maintenance personnel.
Some disk array configurations are removed.
When this message is displayed even if the
device is installed properly, contact your reseller
from which you purchased the product or
consult maintenance personnel.
241
configuration.

Advertisement