 System front view
Server
blade [1]
Server
Server
blade [2]
blade [0]
Power supply
module slot [0]
A
BUZZER button (BZR)
Stops the buzzer.
B
Forcible power off button (POFF)
Press and hold this button for 4 or more seconds, and the system power is
turned off forcibly.
To reboot the system, turn off and then on the circuit breaker to allow AC
power to flow to the power supply module.
C
Power light emitting diode (LED) (PWR)
Lights solid green when the main power of the server blade is on.
Lights solid orange when all server blades are powered off.
Blinks orange during initialization when power is supplied to the server chassis.
D
ERR LED (ALM)
Lights solid red when an error occurs in the server chassis.
E
NODE LED (NODE)
Lights solid orange when an error occurs in a server blade.
Server
Server
blade [4]
blade [3]
Power supply
Power supply
module slot [1]
module slot [2]
16
Server
blade [6]
Server
Server
blade [5]
blade [7]
Front panel
Power supply
module slot [3]
C
D
A
E
F
G
H
I
B