Hitachi Compute Blade 2000 User Manual page 293

Hide thumbs Also See for Compute Blade 2000:
Table of Contents

Advertisement

Message
All of the disks from your previous configuration are
gone. If this is an unexpected message, then please
power off your system and check your cables to
ensure all disks are present.
Press any key to continue, or 'C' to load the
configuration utility.
Press <Ctrl> <H> for WebBIOS.
Your battery is bad or missing, and you have VDs
configured for write-back mode. Because the battery
is not usable, these VDs will actually run in write-
through mode until the battery is replaced.
Multibit ECC errors were detected on the controller.
DIMM on the controller needs replacement. If you
continue, data corruption can occur.
Press 'X' to continue or else power off the system
and replace the DIMM module and reboot. If you
have replaced the DIMM please press 'X' to
continue.
Multiple Single-bit ECC errors were detected during
the previous boot of the controller. DIMM on the
controller needs replacement.
If you continue, data corruption can occur.
Press 'X' to continue or else power off the system
and replace the DIMM module and reboot. If you
have replaced the DIMM please press 'X' to
continue.
Single-bit overflow ECC errors were detected during
the previous boot of the controller. DIMM on the
controller needs replacement.
If you continue, data corruption can occur.
Press 'X' to continue or else power off the system
and replace the DIMM module and reboot. If you
have replaced the DIMM please press 'X' to
continue.
Description
All hard disks with disk array configuration
information have been removed.
When this message is displayed even if the
device is installed properly, contact your reseller
from which you purchased the product or
consult maintenance personnel.
Press the [C] key while this message is
displayed, MegaRAID WebBIOS will start.
When this message is displayed, press the [Ctrl]
and [H] keys at the same time to start
MegaRAID WebBIOS.
Write cache is not enabled because MegaRAID
Storage Manager has set the write policy (write
cache setting) to Write Back.
Change the write policy setting from MegaRAID
WebBIOS referring to
for disk
arrays.
Do not change the write cache from the current
MegaRAID Storage Manager.
An error has occurred in the cache memory of
the disk array controller.
When this message is displayed, contact your
reseller from which you purchased the product
or consult maintenance personnel.
242
Changing the write policy

Advertisement

Table of Contents
loading

Table of Contents