– Place electrical wiring harnesses on the bodywork.
– Remove the vacuum hose -2- at the vacuum unit for charge
pressure control.
– Disconnect the vacuum hose -3- at the cable for vacuum set‐
ting element of the radiator flap for exhaust gas recirculation.
– Disconnect vacuum line at the tandem pump.
– Loosen change-over valve for exhaust gas recirculation radi‐
ator - N345- at the bracket.
– Lay changeover valve for radiator of exhaust gas recirculation
- N345- with connected hoses to the side.
– Detach oil intake hose -1- from exhaust turbocharger.
– Remove oil supply pipe.
– Pull the vacuum hose -arrow- off the brake servo unit.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
– Remove coolant hose -arrow- at coolant fitting.
– Disconnect the plug from the coolant temperature sender -
G62 - and detach the electrical wiring.
Octavia II 2004 ➤ , Octavia II 2010 ➤
2.0/100; 103 kW TDI PD Engine - Edition 01.2018
1. Removing and installing cylinder head
87