♦ Protective gloves
Condition
The fuel tank must not be more than
Removing
Note
Drain the fuel tank
⇒ page 155
Safety precautions when working on the fuel supply system
⇒ page 3
.
Observe the regulations concerning cleanliness when working
on the fuel supply/injection system
– Switch off ignition and pull out ignition key.
– Removing rear seat bench ⇒ Body Work ⇒ Rep. gr. 72 .
– Remove the cover from the fuel delivery unit.
Note
On vehicles with auxiliary heating, the plug connection for the
dosing pump - V54- must also be disconnected.
Two types of fuel delivery units are installed in the vehicles,
which can be recognized on the different flanges.
Fuel delivery unit type one
– Disconnect the plug as well as the black fuel feed line -1- and
the blue fuel return-flow line -2- from the flange.
Note
Press in the securing ring in order to unlock the line.
For vehicles with auxiliary heating the suction hose for the
dosing pump - V54- must be pulled out additionally (open low‐
er clamp).
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not permitted
unless authorised by ŠKODA AUTO A. S. ŠKODA AUTO A. S. does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by ŠKODA AUTO A. S.�
– Open lock ring with the wrench - T30101 - .
– Pull closing flange and gasket ring for fuel pump out of the
opening of the fuel tank and place to the side with the con‐
nected lines.
2.0/100; 103 kW TDI PD Engine - Edition 01.2018
1
/ 3 full.
.
⇒ page 4
.
1. Removing and installing parts of the fuel supply system
Octavia II 2004 ➤ , Octavia II 2010 ➤
163