Maintenance Commands

test port

Use test port to run hardware diagnostic tests on an individual port circuit. In
most cases, tests are performed on hardware connected to the port.
Action/
Object
Qualifier
test port
location
short
long
repeat
number
clear
schedule
1
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence. SEE WARNING BELOW.
2
See the Report Scheduler and System Printer feature specification for more details.
!
WARNING:
Since the "clear long" options clear all counters if tests pass, it is possible for
firmware counters to be cleared even when a problem exists. In some cases
customer service might degrade since calls may be routed over defective
equipment.
578
Issue 5 October 2002
Qualifier Description
PCSSpp
Option for a brief series of nondestructive
diagnostic tests.
Option for a longer, more comprehensive
series of both destructive and
nondestructive diagnostic tests.
How many times each test in the sequence
is repeated (1-100)
This option causes the test sequence
(short or long) to repeat until the alarm (if
any) is cleared or a single test in the
1
sequence fails.
Use the screen to schedule execution of
the command. The command is placed in
the command queue and is executed at the
specified time. The information displayed
by the command is sent to the system
printer instead of the screen.
Examples:
test port 01c1101 l
test port 01c1101 l schedule
test port 02e1502 sh r 2
test port 02d1201 r 4
test port 01c1101 c