M/T-Anl (Maintenance/Test Analog Port) - Avaya S8700 Maintenance Manual

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

M/T-ANL (Maintenance/Test Analog Port)

M/T-ANL (Maintenance/Test Analog
Port)
MO's Name (in
Alarm
Alarm Log)
Level
M/T-ANL
Minor
M/T-ANL
Warning
1.
UU is the universal cabinet number (1–64). C is the carrier designation (A, B, C, or D). SS is the number of the
slot where the circuit pack resides (01–10). pp is the 2-digit port number (01, 02,...).
The Maintenance/Test analog port is port number 1 on the TN771D Maintenance/
Test circuit pack. This port is used by the Automatic Transmission Measurement
System (ATMS) as an Originating Test Line (OTL) or Terminating Test Line (TTL)
for test calls over analog trunks. For more details, see "Automatic Trunk
Transmission System" in
Figure 8-26
M/T-ANL maintenance ensures that the analog trunk's testing function is
operating correctly. Although an M/T-ANL alarm can reduce service, it will not
block service. To accurately measure the performance and health of analog
trunks, replace an alarmed TN771D when a new circuit pack is available.
PBX originating
TN771
TDM Bus
Figure 8-26. ATMS Tie Trunk Test Call
555-233-142
Initial Command to Run
test port UUCSSpp l
release port UUCSSpp
Chapter 5, ''Additional Maintenance
shows a typical ATMS configuration.
the test call
Originating
Test Line
(OTL)
Tie Trunk
Circuit Pack
1
Full Name of MO
Maintenance/Test analog port
Maintenance/Test analog port
PBX terminating
the test call
TN771
Terminating
Test Line
(TTL)
Tie
Trunk
Facilities
Tie Trunk
Circuit Pack
Issue 1 May 2002
Procedures''.
TDM Bus
8-821