Monitoring System Process Information; Table 125: Summary Of System Process Information Output Fields - Juniper JUNOS OS 10.4 - FOR EX REV 1 Manual

For ex series ethernet switches
Table of Contents

Advertisement

Complete Software Guide for Junos
Table 124: Summary of the Key Output Fields for Chassis Information (continued)
Field
Name/Value
Related
Documentation

Monitoring System Process Information

Purpose
Action
Meaning

Table 125: Summary of System Process Information Output Fields

Field
PID
Name
State
654
®
OS for EX Series Ethernet Switches, Release 10.4
Values
Displays resource details:
State:
—Held in reset because of errors.
Dead
—The FPC is running diagnostics.
Diag
—Held in reset.
Dormant
Empty
—No FPC is present.
Online
—The FPC is online and running.
Probed
—Probe is complete. The FPC is awaiting restart of the Packet Forwarding
Engine (PFE).
—The FPC is waiting for the probe operation to start.
Probe-wait
Total CPU DRAM
—Date and time the switch was last rebooted.
Start time
Monitoring System Process Information on page 654
Monitoring System Properties on page 650
Dashboard for EX Series Switches on page 630
Use the monitoring functionality to view the processes running on the switch.
To view the software processes running on the switch in the J-Web interface, select
Monitor>System View>Process Details.
To view the software processes running on the switch in the CLI, enter the following
command.
show system processes
Table 125 on page 654 summarizes the output fields in the system process information
display.
The display includes the total CPU load and total memory utilization.
Values
Identifier of the process.
Owner of the process.
Current state of the process.
—Total DRAM, in megabytes, available to the FPC.
Additional Information
Copyright © 2010, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junos os 10.4

Table of Contents