Members; Table 130: Show Chassis Environment Fpc Output Fields - Juniper JUNOS OS 10.4 - FOR EX REV 1 Manual

For ex series ethernet switches
Table of Contents

Advertisement

Complete Software Guide for Junos
Required Privilege
Level
List of Sample Output
Output Fields

Table 130: show chassis environment fpc Output Fields

Field Name
Field Description
Status of the FPC:
State
(M40e and M160 routers only) Temperature of the air flowing past the FPC.
Temperature
(M320 routers only) Temperature of the air flowing into the chassis.
Temperature Intake
(T Series routers only) Temperature of the air flowing past the top of the FPC.
Temperature Top
(M120 and M320 routers only) Temperature of the air flowing out of the chassis.
Temperature Exhaust
(T Series routers only) Temperature of the air flowing past the bottom of the FPC.
Temperature Bottom
720
®
OS for EX Series Ethernet Switches, Release 10.4
EX3200 switches and EX4200 standalone switches—Replace
EX4200 switches in a Virtual Chassis configuration—Replace
from 0 through 9 (switch's member ID).
EX8208 switches—Replace
EX8216 switches—Replace
view
show chassis environment fpc (M120 Router) on page 721
show chassis environment fpc (M160 Router) on page 722
show chassis environment fpc (M320 Router) on page 722
show chassis environment fpc (MX240 Router) on page 723
show chassis environment fpc (MX480 Router) on page 724
show chassis environment fpc (MX960 Router) on page 725
show chassis environment fpc (T Series Core Routers) on page 726
show chassis environment fpc lcc (TX Matrix Router) on page 726
show chassis environment fpc lcc (TX Matrix Plus Router) on page 727
Table 130 on page 720 lists the output fields for the
command. Output fields are listed in the approximate order in which they appear.
—FPC is not detected by the router.
Unknown
Empty
—No FPC is present.
—FPC is detected by the chassis daemon but is either not supported by the current version
Present
of the Junos OS, or the FPC is coming up but not yet online.
—FPC is in intermediate or transition state.
Ready
—Intermediate state during which the FPC is coming up but not yet online, and the
Announce online
chassis manager acknowledges the chassisd FPC online initiative.
—FPC is online and running.
Online
—FPC is powered down.
Offline
Diagnostics
—FPC is set to operate in diagnostics mode.
with a value from 0 through 7 (line card).
slot
slot
with a value from 0 through 15 (line card).
show chassis environment fpc
Copyright © 2010, Juniper Networks, Inc.
with 0.
slot
with a value
slot

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junos os 10.4