6 Multi-Button
Trigger Condition Tab
The Trigger Condition tab is displayed in Advanced mode.
Input Condition
The Button is enabled and operational while the condition is satisfied. The Button is disabled and not operational
while the condition is not satisfied.
Example: When Trigger Type is While ON and Device Address is LM0
While LM0 is 0, the condition is not satisfied and the Button is not operational.
While LM0 is 1, the condition is satisfied and the Button is operational.
Trigger Type:
Selects the condition to enable the Button from the following.
Always enable: The Button is always enabled.
While ON:
8-132
LM0 :
0
Condition
Not
satisfied
LM0 : 1
Condition
Satisfied
Button state
Enables the Button when the value of device address is 1.
1
Value of
device address
0
Button state
Disabled
WindO/I-NV4 User's Manual
MICRO/I
Button
Does not
operate
Button
Operates
Always enabled
Enabled
Disabled
Enabled
Enabled
Disabled