IDEC MICRO/I HG4G-CJT22 F-B Series User Manual page 567

Micro/i operator interfaces for windo/i-nv4
Table of Contents

Advertisement

Trigger Condition Tab
The Trigger Condition tab is displayed in Advanced mode.
Input Condition
The Potentiometer is enabled and operational while the condition is satisfied. The Potentiometer is disabled and not
operational while the condition is not satisfied.
Example: When Trigger Type is While ON and Device Address is LM0
While LM0 is 0, the condition is not satisfied and the Potentiometer is not operational.
While LM0 is 1, the condition is satisfied and the Potentiometer is operational.
Trigger Type:
Selects the condition to enable the Potentiometer from the following.
Always enable: The Potentiometer is always enabled.
While ON:
LM0 :
0
Condition
Not
satisfied
LM0 : 1
Condition
Satisfied
Potentiometer
state
Enables the Potentiometer when the value of device address is 1.
1
Value of
device address
0
Potentiometer
state
Disabled
Enabled
WindO/I-NV4 User's Manual
MICRO/I
Button
Does not
operate
Button
Operates
Enabled
Disabled
Enabled
9 Potentiometer
8
Enabled
Disabled
8-165

Hide quick links:

Advertisement

Table of Contents
loading