Select this check box to display text on the MICRO/I in high-quality fonts. The Japanese or European font is
replaced with the high-quality fonts depending on the magnification.
To use high-quality fonts, the fonts must be downloaded to the MICRO/I at the same time as the project. To
download fonts, specify the high-quality fonts under Optional Fonts to be downloaded in the Font Settings tab.
For details on high-quality fonts, refer to Chapter 2 "High-quality Fonts" on page 2-10.
Enable Two-point Push
Select this check box to enable two-point push for touch switches. When two-point push is enabled, the bottom
switch and the switch above it operate in order.
On an analog touch panel, this function operates two overlapping switches when the two are pressed. This is not a
function to simultaneously operate two touch switches when they are both pressed.
Enable Low Battery Warning
Select this check box to display a warning message when the backup battery is dead.
This option also displays a warning message when it is time to replace the battery.
Show script error
Select this check box to display an error message on the screen when a script error occurs.
Script error information is saved to the HMI Special Data Registers (LSD52 and LSD53). For details, refer to
Chapter 20 "1.4 Script Error" on page 20-4.
System Language
Selects the display language for the Maintenance screen, System Mode screens, Device Monitor, and Adjust
Brightness screen as English or Japanese.
For details, refer to Chapter 34 "1 Maintenance Screen" on page 34-1.
Use System Area
The System Area is an area of predetermined device addresses to control the screen and communicate error
information and time information between the MICRO/I and the external device. Select this check box to use the
System Area. For details, refer to "System Area" on page 4-30.
Device Address: Specifies the word device to use as the System Area. The System Area is allocated starting from the
configured device address.
Click
2 "5.1 Device Address Settings" on page 2-68.
Use System Area 3, 4:
Clear Keypad bit in System Area automatically: Select this check box to automatically set the System Area 2
Flashing Cycle
Selects the cycle when flashing (displaying a drawing object by switching it on and off at a fixed interval) drawings
and parts as 1.0 sec or 0.5 sec.
*2 HG5G/4G/3G/2G-V, HG4G/3G, HG2G-5F/-5T, HG1G only
*2
to display the Tag Editor. For the device address configuration procedure, refer to Chapter
Select this check box to use System Area 3 and 4.
numerical input setting and character input setting bits to 0 after
they have been set to 1.
The System Area 2 bits cleared by this function are as follows.
Numerical input setting complete (address number+3, bit 0)
Numerical input setting cancel (address number+3, bit 1)
Character input setting complete (address number+3, bit 5)
Character input setting complete (address number+3, bit 6)