4 Popup Screen
4
Popup Screen
The Popup Screen that is displayed on the Base Screen when the MICRO/I is in Run Mode. The size and coordinates
of the screen can be specified and this screen can also be moved on the Base Screen.
4.1 Properties of Popup Screen Dialog Box
General Tab
●
Screen Type
■
Select Popup Screen for the screen type.
You can only select the screen type when creating a new screen.
Number
■
Enter the Popup Screen's screen number (1 to 3015).
However, screen numbers 3001 to 3015 are Popup Screens for standard Keypads for Numerical Input and Character
Input.
Font
■
Select the font to use for the title from the following items:
Japanese, European, Chinese, Taiwanese, Korean, Central European, Baltic, Cyrillic
This option can only be selected when Use Text Manager is cleared.
Use Text Manager
■
Select this to use text registered in the Text Manager for the screen title.
However, the text color is white, not the color set in the Text Manager.
Text ID
■
Specify the Text Manager ID number (1 to 32000) to use text registered in the Text Manager. Click
Text Manager.
This option can only be set when Use Text Manager is selected.
5-20