2 Multi-State Lamp
While OFF: Displays the Multi-State Lamp when the value of device address is 0.
While satisfying the condition:
Data Type:
Selects the type of data handled by the conditional expression for the visible condition.
This option can only be configured if While satisfying the condition is selected for Trigger Type.
For details, refer to Chapter 2 "1.1 Available Data" on page 2-1.
Device Address: Specifies the bit device or the bit number of the word device to serve as the visible condition.
This option can only be configured when While ON or While OFF is selected for Trigger Type.
Click
"5.1 Device Address Settings" on page 2-68.
Condition:
Specifies the conditional expression for the visible condition.
This option can only be configured when While satisfying the condition is selected for Trigger
Type.
Click
configuration procedure, refer to Chapter 2 "5.2 Setting Conditional Expressions" on page 2-71.
Comment:
Used for entering a comment for the visible condition. The maximum number is 80 characters.
9-28
1
Value of
device address
0
Multi-State
Lamp state
Show
Displays the Multi-State Lamp when the condition is satisfied.
Satisfied
Condition
Not satisfied
Multi-State
Lamp state
Hide
to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2