• The value of the Receiving Character Time Out (address number+0, bit 15) of the Status Device
Address LDR110 remains 0.
Value of Device Address LM100 when
Trigger Condition is While ON
Value of Completed Device Address
Value of Receiving Character Time Out
(address number+0, bit 15)
of Status Device Address LDR110
When the Receiving Character Time Out duration exceeds until the data of second byte starts to be
received after the data of first byte is received, the value of the Receiving Character Time Out (address
number+0, bit 15) of the Status Device Address LDR110 changes to 1 and the Completed Device
Address LM101 remains 0. In addition, when the value of the Trigger Condition device address LM100
changes from 0 to 1, the value of LDR110 (address number +0, bit 15) changes to 0.
Value of Device Address LM100 when
Trigger Condition is While ON
Value of Completed Device Address
Value of Receiving Character Time Out
(address number+0, bit 15)
of Status Device Address LDR110
*1
Inching Function
: Displays whether or not the inching function is used. Double clicking the cell switches between
the Enable and the Disable. This can only be set for the User Communication 1.
By using the inching function, data is transmitted at the specified execution interval.
Inching refers to the inching operation of the drive section. It is a general term for drive operations that
repeatedly start and stop in small increments for each operation, such as starting and stopping the drive
section when a push button or switch is pushed and released.
Execution Interval (x10 msec)
The command cannot be sent at the specified execution interval if the following conditions occur:
• The transmission processing for a command cannot be completed within the time set by the Execution
Interval.
⇒ Set the Execution Interval to a time longer than it takes to send the command.
• The inching function was used at the same time as user communication transmission or receive
processing.
⇒Do not use transmission commands, receive commands and commands for inching function at one
time.
One frame is transmitted with no character spacing.
*1 HG1P only
First byte of receive data
Receive command
1
0
1
LM101
0
1
0
First byte of receive data
Receive command
1
0
1
LM101
0
1
0
*1
: Specifies the interval to send the commands for inching function as 40 to 1000 (20
ms increments).
This option can only be set when the Enable is selected in the Inching Function.
WindO/I-NV4 User's Manual
3 Project Settings Dialog Box
Receiving Character Time Out duration
Second byte of receive data
Receiving Character Time Out duration
Second byte of receive data
4