Properties Of Bit Button Dialog Box - IDEC MICRO/I HG4G-CJT22 F-B Series User Manual

Micro/i operator interfaces for windo/i-nv4
Table of Contents

Advertisement

1 Bit Button

1.3 Properties of Bit Button Dialog Box

This section describes items and buttons in the Properties dialog box.
General Tab
Part Name
Enter a name for the part. The maximum number is 20 characters.
>>OFF Text, >>ON Text
Applies the text entered in the Part Name field to the Text field under the OFF or ON fields on the Registration
Text tab. This is used as the Registration Text when the button is OFF or ON.
To specify the Registration Text to use when the button is ON, select the Set by State check box on the
Registration Text tab. If left unchecked, the same Registration Text assigned for the OFF state is
displayed for the ON state as well.
Action Mode
Select the behavior of the button from the following:
Set:
Pressing the button writes a 1 to the bit device.
Operation and
Reset:
Pressing the button writes a 0 to the bit device.
Operation and
8-4
view
Initial image
Action
Data written
view
Initial image
Action
Data written
WindO/I-NV4 User's Manual
Press
Release
Press
Write
Write
1
1
Press
Release
Press
Write
Write
0
0
Release
Release

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents