Number of Scroll:
Specifies the number of points of data to scroll the chart left or right (1 to the Screen size (Horizontal)) when
stopping the chart display.
This option can only be configured when the Stop updating the display and display the saved data check
box is selected.
Specify by Device Address:
Display data from specified date: When stopping the chart display, to display the chart with the specified Start
Start Date and Time:
Specify displaying period:
End Date and Time:
• The maximum number of data that can be displayed is the number of dots on the X-axis of the graph
(the horizontal size of the area displaying the graph). When the number of data from Start Date to End
Date exceeds the number of dots on the X-axis, thinned out data is displayed.
Number of dots on X-axis
120
100
80
60
40
20
0
-20
0
10
20
30
• If Start Date and End Date are the same or End Date is earlier than Start Date, the chart display
will not be updated.
Select this check box and specify a source word device to specify the Number of
Scroll using the value of the specified device address.
Click
to display the Tag Editor. For the device address configuration procedure,
refer to Chapter 2 "5.1 Device Address Settings" on page 2-68.
When MICRO/I starts operation, it copies the value of Number of Scroll as the
initial value to the device address.
Date as the left end, select this check box and specify the bit device or the bit
number of the word device to control the display.
Click
to display the Tag Editor. For the device address configuration procedure,
refer to Chapter 2 "5.1 Device Address Settings" on page 2-68.
Displays the chart for Display Points with Start Date as the left end when the
value of device address changes from 0 to 1.
Specifies the Start Date as the values of word devices for the data to display in the
chart.
Click
to display the Tag Editor. For the device address configuration procedure,
refer to Chapter 2 "5.1 Device Address Settings" on page 2-68.
For address number assignment, refer to "Specifying Date and Time with Values of
device addresses" on page 11-33.
This option can only be configured when Display data from specified date
check box is selected.
To specify the range of data displayed on the chart, select this check box and
specify the bit device or the bit number of the word device to control the display.
Click
to display the Tag Editor. For the device address configuration procedure,
refer to Chapter 2 "5.1 Device Address Settings" on page 2-68.
Displays the chart from Start Date as the left end to End Date when the value of
device address changes from 0 to 1.
This option can only be configured when Display data from specified date
check box is selected.
Specifies the End Date for the data to display in the chart.
Click
to display the Tag Editor. For the device address configuration procedure,
refer to Chapter 2 "5.1 Device Address Settings" on page 2-68.
For address number assignment, refer to "Specifying Date and Time with Values of
device addresses" on page 11-33.