5 Script Command
While satisfying the condition:
Fixed Period:
Data Type
Selects the data type to be handled by the condition formula.
Can only be set if Satisfy the condition or While satisfying the condition is selected as Trigger Type.
For details, refer to Chapter 2 "1.1 Available Data" on page 2-1.
Device Address
Specifies the bit device or the bit number of the word device to serve as condition.
Can only be set if Rising-edge or Falling-edge is selected as Trigger Type.
Click
to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2 "5.1 Device
Address Settings" on page 2-68.
Condition
Sets the condition formula.
Can only be set if Satisfy the condition or While satisfying the condition is selected as Trigger Type.
Click
to display the Trigger Condition Settings dialog box. For the conditional expression configuration
procedure, refer to Chapter 2 "5.2 Setting Conditional Expressions" on page 2-71.
Period
Sets the period for command execution from 1 to 3600 (seconds).
Can only be set if Fixed Period is selected as Trigger Type.
Comment
Used for entering comments about trigger conditions. The maximum number is 80 characters.
12-36
The command continues being executed while the condition is satisfied.
Satisfied
Condition
Not satisfied
Action
Execution
Command executes within a fixed time interval.
Fixed time interval
Action
Execution
WindO/I-NV4 User's Manual
Execution Execution
Fixed time interval
Execution
Execution
Execution Execution
Fixed time interval
Execution