IDEC MICRO/I HG4G-CJT22 F-B Series User Manual page 527

Micro/i operator interfaces for windo/i-nv4
Table of Contents

Advertisement

If Upload PLC Program is selected.
Source:
Specify the source PLC connected to the MICRO/I. The PLC type is configured in the Project Settings
dialog box, on the Communication Driver Network tab. For details, refer to Chapter 4 "3.4
Communication Driver Network Tab" on page 4-50.
Interface:
If serial interface is selected for Interface.
Slave Number:
External Device Name:
If Ethernet is selected for Interface.
Select from the following method:
Specify External Device ID:
External Device Name: The name of the specified PLC is displayed here.
Specify IP Address:
Destination: Specify where to save the PLC program uploaded from the PLC connected to the MICRO/I. Select the
type of external memory: SD Memory Card
Location:
A uploaded PLC program using the Data Transfer function is saved as a ZLD Project File(.zld).
*1 HG5G/4G/3G/2G-V, HG4G/3G, HG2G-5F only
Select the communication interface in which the MICRO/I is connecting to the upload
source PLC from serial interface or Ethernet. For details, refer to Chapter 4 "Interface
Configuration" on page 4-35.
Specify the slave number of the upload source PLC (0 to 31).
The name of the specified PLC is displayed here.
Specify the External Device ID (0 to 31) of the upload source PLC. This is
the External Device ID number set in the Project Settings dialog box,
on the Communication Driver Network tab.
Specify the IP address and port number of the upload source PLC.
Specify the location of the folder where the uploaded PLC program will be saved. The
maximum number is 247 characters.
Example: To save it to the folder "Uploaded_Program" on an SD memory card or USB flash drive:
Uploaded_Program
WindO/I-NV4 User's Manual
*1
or USB Flash Drive.
6 Multi-Button
8
8-125

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents