IDEC MICRO/I HG4G-CJT22 F-B Series User Manual page 968

Micro/i operator interfaces for windo/i-nv4
Table of Contents

Advertisement

3 Alarm Log Settings Dialog Box
File Name:
Enter the file name for the output data or shows the file name.
The default is "ALMHTA.CSV". To change the file name, enter a new file name. The maximum
number is 120 characters (including the extension).
Specify File Name by Value of Device Address: Select this check box to specify the name of the file
Add Device Address data to File Name: Select this check box to add the bottom three digits of the
Add Time Stamp:
Realtime Output:
Set limit on files:
13-24
(File Name Device Address):
Example: When the device address specified by (File Name Device Address) is LDR100 and the
text to set is "IDEC":
(File Name Device Address)
The file name at this time becomes "IDEC.CSV".
(File Name Device Address): Specifies the word device that is the source for the value to add to
Example: File Name is "ALMHTA" and the value of the device address configured by (File Name
Device Address) is 123, the file name is "ALMHTA123.CSV".
Selects the format of the output date and time to add to the file name for the
output data.
None, YY, YY+MM, YY+MM+DD
The format is YYMMDD (YY: year, MM: month, DD: day).
Example: File Name is "ALMHTA" on September 15 2013
YY:
YY+MM:
YY+MM+DD:
Select this check box to forcibly output the data and save it to file at the desired
timing.
(Trigger Device Address):
Specifies the upper limit (1 to 100) when limiting the number of files to be
output.
WindO/I-NV4 User's Manual
for the output data with the value of the device
address configured by (File Name Device Address).
Specifies the word device that is the source of the data to use as
the file name. The file name is set by reading the values
sequentially from the starting device address specified with the
File Name Device Address and handling those values as character
data up to the character before NULL (00).
The maximum number of device addresses is 40 (80 single-byte
characters). You can only specify an internal device. For the
device address configuration procedure, refer to Chapter 2 "5.1
Device Address Settings" on page 2-68.
LDR100
' I ' 'D'
4844 (Hex)
LDR101
'E' 'C'
4543 (Hex)
LDR102
(NULL)
0000 (Hex)
value of the device address configured by (File Name Device
Address) to the end of the file name for the output data.
the file name. For the device address configuration procedure, refer
to Chapter 2 "5.1 Device Address Settings" on page 2-68. This
option can only be configured when the Add Device Address
data to File Name check box is selected.
ALMHTA_13
ALMHTA_1309
ALMHTA_130915
Specifies the bit device or the bit number of the word device to
serve as the condition to forcibly output the data. You can only
specify an internal device. For the device address configuration
procedure, refer to Chapter 2 "5.1 Device Address Settings" on
page 2-68.
Data is output to file when the value of Trigger Device Address
changes from 0 to 1.