IDEC MICRO/I HG4G-CJT22 F-B Series User Manual page 636

Micro/i operator interfaces for windo/i-nv4
Table of Contents

Advertisement

2 Character Input
Coordinates X, Y:
Data Format
Specifies the digits to display.
Input Digits:
Display Digits:
Input Method
These options configure the destination for the character codes for the entered text.
Destination Device Address:
Specifies the destination word device for the character codes for the entered text.
Click
to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2 "5.1 Device
Address Settings" on page 2-68.
Use Reference Device Address
Select this check box and specify a device address to change the destination word device by the value of this
device address.
Click
to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2 "5.1 Device
Address Settings" on page 2-68.
For details on indirect writing, refer to Chapter 2 "Indirect Read and Indirect Write Settings" on page 2-5.
Write NULL (0x00) after the end of the string:
Select this check box to write NULL (0x00) to all device addresses from the end of the string to the address
number specified by Input Digits if the length of the input string is less than Input Digits.
Example: If Input Digits is 10 and a string with a length of 5 was input
Character Input
device address
Enter MICRO
(Length of the string is 5)
Character Input
device address
*1 Advanced mode only
10-30
Specifies the display location of the popup screen configured as the keypad.
With the upper-left corner of the screen as the origin, the X and Y coordinates are the
upper-left corner of the popup screen.
This option can only be configured when Standard(Half-Width Character),
Standard(Hiragana) or Popup is selected for Type and the Adjust location
automatically check box is cleared.
Specify the coordinates in 1 dot units.
X: 0 to (base screen horizontal size - 1)
Y: 0 to (base screen vertical size - 1)
Specifies the number of digits that can be entered with the Character Input (1 to 127). For
each character to enter, one digit for half-width characters and two digits for full-width
characters is required.
Specifies the number of digits that can be displayed in the Character Input display (1 to 100).
Regardless of half-width or full-width, one digit is required per character.
*1
:
Check box: Selected
HG SERIES
display
'H' 'G'
4847
(Hex)
' ' 'S'
   
2053
(Hex)
Value of
destination
'E' 'R'
   
4552
(Hex)
' I ' 'E'
   
4943
(Hex)
   
'S'
(NULL)
5300
(Hex)
MICRO_
MICRO
display
'M' 'I'
4D49
(Hex)
'C' 'R'
   
4352
Value of
(Hex)
destination
'O'
   
(NULL)
4F00
(Hex)
' I ' 'E'
   
4943
(Hex)
   
'S'
(NULL)
5300
(Hex)
WindO/I-NV4 User's Manual
Check box: Cleared
HG SERIES
'H' 'G'
4847
(Hex)
' ' 'S'
   
2053
(Hex)
   
'E' 'R'
4552
(Hex)
' I ' 'E'
   
4943
(Hex)
'S'
   
(NULL)
5300
(Hex)
MICRO_
MICRO
'M' 'I'
4D49
(Hex)
Values updated
   
'C' 'R'
4352
(Hex)
to 6th character
'O'
   
(NULL)
4F00
(Hex)
   
0000
(NULL)(NULL)
(Hex)
Values are not
updated
   
(NULL)(NULL)
0000
(Hex)
NULL (0x00) is written
from 7th character
and the values of
all 10 characters
are updated

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents