Seat contact
switch
G
Operating Manual GMK6300L
This check is carried out together with the dead man's switch.
Danger of accident if the seat contact switch is faulty!
Always stand inside the crane cab when you do this check.
If you stand next to the crane cab, you may be pushed off the carrier if the
superstructure slews as a result of a faulty dead man's switch.
Checks while stationary
Do not sit down on the crane cab seat.
Do not press any dead man's switch (1).
Move the control levers one after the other for all the crane movements
and check whether all the crane movements are switched off.
Checks during operation
– Dead man's switch
Do not sit down on the crane cab seat.
Press the right dead man's switch (1) and slowly lift the hook block.
With the control lever actuated, let go of the right dead man's switch
and check whether the crane movement comes to a standstill within
approx. 3 seconds.
Repeat the check with the dead man's switch on the left control lever.
– Seat contact switch
Do not press any dead man's switch (1).
Sit down on the crane cab seat and slowly lift the hook block.
With the control lever actuated, stand up and check whether the crane
movement comes to a standstill within approx. 3 seconds.
If the dead man's switch system is not working correctly, do not start work
with the crane but notify Manitowoc Crane Care.
3 112 xxx en
Crane operation
11.1 Before operating the crane
11 - 11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Grove GMK6300L and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Grove gmk6300l-1

Table of Contents

Save PDF