Crane operation
11.3 Crane operation with main boom
11 - 90
– The displayed symbol, e.g. symbol (1) will flash if the control lever is
moved incorrectly.
– If the control lever movement is correct, ECOS will telescope automati-
cally until a change in direction is required. Then the symbol for the new
movement will be displayed, e.g. (2) for Retracting .
– For unloaded movements of the telescoping cylinder (without telescopic
section), symbol (3) is displayed.
Ending teleautomation
The teleautomation will stop when the entered
telescope status is reached.
Move the control lever to its initial position.
Display (1) – teleautomation off.
Cancelling teleautomation
Press button (9) once.
Telescoping stop – teleautomation off:
– Values (1) to (6) are red.
– Display (7) goes out,
– Display (8) – teleautomation off.