Input Table 9 (5I - 2O); Logic Output 1 (I1 Is 0); Logic Output 1 (I1 Is 1) - Siemens SIMOCODE 3UF Programming And Operating Manual

Table of Contents

Advertisement

13.1.12
Table 9 (5I - 2O)
13.1.12.1
Table 9 (5I - 2O)
Table 9 (5I - 2O)
The Truth Table for 2I/1O consists of:
● 5 plugs
● 1 logic component
● 2 socket (Truth Table Outputs).
You can choose from four possible input conditions the one with which to generate an output
signal.
In total, 1 Truth table (9) are available for the SIMOCODE pro V PN Basic Units.
13.1.12.2

Input Table 9 (5I - 2O)

Input Table 9 (5I - 2O)
Activate the Truth Table with any signal (any sockets, e.g. device inputs, control bits from
PROFINET, etc).
13.1.12.3

Logic output 1 (I1 is 0)

Logic output 1 (I1 is 0)
If input 1 = 0 you can select the input conditions for which you want to generate an output
signal from 16 possible input conditions.
13.1.12.4

Logic output 1 (I1 is 1)

Logic output 1 (I1 is 1)
If input 1 = 1 you can select the input conditions for which you want to generate an output
signal from 16 possible input conditions.
SIMOCODE PRO V PN FDI
Programming and Operating Manual, 05/2020, A5E44499659002A/RS-AA/001
Logic Modules
13.1 Truth Tables
117