COPIER> ADJUST> FEED-ADJ
REG-CST2
Storage side regst adj dspl:Pikup deck2
Lv.1 Details
Display the side registration misalignment position amount of the
storage of the POD upper deck.
As an indicator when side registration the storage is adjusted.
Use case
When adjusting the side registration of the storage in case that the
correction is not enough at the active registration.
Adj/set/operate method 1) Report the side registration correction amount of each pickup
cassette at the last feed.
2) Display the 1) value on the control panel (rear: +, front: -, unit:
mm)
3) Adjust the side registration position of pickup cassette according
to the displayed value.
If the value is within the adjustment range of active registration (-1
to 1 mm), adjustment is not necessary.
Caution
• After the side registration adjustment of storage, feed the paper
and check the result.
• Do not move the storage that is adjusted for transparency other
than user's request.
Display/adjust/set range -10 to 10
Unit
1 mm
Appropriate target value -6 to 6
Default value
0
Supplement/memo
On [side registration shift amount offset] that is the fixing assembly
paper edge measure, the value is displayed regardless of the side
registration correction amount.
8
Service Mode > COPIER > ADJUST (Adjustment Mode) > FEED-ADJ
8
Service Mode > COPIER > ADJUST (Adjustment Mode) > FEED-ADJ
COPIER> ADJUST> FEED-ADJ
REG-CST3
Storage side regst adj dspl:Pikup deck3
Lv.1 Details
Display the side registration misalignment position amount of the
storage of the POD middle deck.
As an indicator when side registration the storage is adjusted.
Use case
When adjusting the side registration of the storage in case that the
correction is not enough at the active registration.
Adj/set/operate method 1) Report the side registration correction amount of each pickup
cassette at the last feed.
2) Display the 1) value on the control panel (rear: +, front: -, unit:
mm)
3) Adjust the side registration position of pickup cassette according
to the displayed value.
If the value is within the adjustment range of active registration (-1
to 1 mm), adjustment is not necessary.
Caution
• After the side registration adjustment of storage, feed the paper
and check the result.
• Do not move the storage that is adjusted for transparency other
than user's request.
Display/adjust/set range -10 to 10
Unit
1 mm
Appropriate target value -6 to 6
Default value
0
Supplement/memo
On [side registration shift amount offset] that is the fixing assembly
paper edge measure, the value is displayed regardless of the side
registration correction amount.