Symptom

0111/0C10/0112 Jam Code due to failure of the transfer high voltage PCB

[Inspected by Canon Inc.]
Description
0111/0C10/0112 Jam occurred.
- 0111: Fixing Outlet Sensor Delay Jam
- 0C10: Fixing Toenail Jam Delay Jam
- 0112: Inner Delivery Sensor Delay Jam
Cause
The transfer high voltage PCB is defective, which causes a jam.
Field Remedy
When the symptom occurs, replace the transfer high voltage PCB (FM4-1095) by following the steps below.
1) Open the front cover, and turn the fixing feed unit pressure lever in the counterclockwise direction to pull
out the fixing feed unit.
2) Push and release the release springs at both sides of the rail, and then further pull out the fixing feed unit
until it stops.
3) Remove the 1 screw, and then detach the fixing feed right front cover.
4) Lift the ETB unit in the direction of the arrow.
pg. 59