1
Product Overview > Product Lineup > Pickup and delivery system options > Required options and conditions
C. imagePRESS 1110 /1110+ IPC communication option (overseas only)
Paper Folding Unit-F1
iPR 1110
Finisher-AG1
Document
/Saddle Finisher-AG2
Insertion Unit-F1
Professional Puncher
Professional
Integration Unit-A1
Puncher-B1
■ Required options and conditions
● Pickup system options
Product Name
POD Deck-C1
There is no particular required options and conditions
Paper feed system: air separation
Paper feed capacity: max 4,000 sheets
Paper types: thick paper/ thin paper/ coated paper
Paper sizes: B5 to 13" x 19.2"
Paper weight: 52 to 300g/m
Double feed detection: Yes
I/F: ARCNET
Secondary POD Deck-C1
Requires POD deck C1
Overseas model iPR 1135 / 1135+ /1125 / 1125+: max. two units
can be connected
Overseas model iPR 1110 /1110+: one unit only
Japan model (all models): one unit only
I/F: ARCNET
Multi Drawer Document
Can only be connected to Document Insertion Unit-F1
Insertion Unit-A1
Paper feed capacity: max 4,000 sheets
Paper types: thick paper/ thin paper/ coated paper
Paper sizes: B5 to 13" x 19.2"
Paper weight: 52 to 300g/m
Double feed detection: Yes
I/F: ARCNET
Document Insertion Unit-F1
Option for iPR 1110 /1110+.
Can only be connected to Multi Drawer Document Insertion Unit-A1
Paper feed capacity: max 400 sheets (200 sheets each in upper
and lower trays)
Paper types: plain paper/ recycle paper/ color paper / thick paper /
coated paper
Paper sizes: B5 to 13" x 19.2"
Paper weight: 52 to 300g/m
I/F: ARCNET, Serial
1
Product Overview > Product Lineup > Pickup and delivery system options > Required options and conditions
: IPC I/F
: Serial I/F
Required options / conditions, etc.
2
2
2
Product Name
Tab Feeding Attachment-E1
Cassette heater (200V)
F-1-4
Required options / conditions, etc.
Main unit, POD Deck-C1, Secondary POD Deck-C1, Multi Drawer
Document Insertion Unit-A1 option.
One provided as standard for each POD Deck-C1 and Multi Drawer
Document Insertion Unit-A1.
Multi Insertion Unit:
Can be used on middle/lower deck and cannot be used on upper
deck.
Main unit, POD Deck-C1, Secondary POD Deck-C1, Multi Drawer
Document Insertion Unit-A1 option
For Japan model only.
230V region: service part
120V region: none
1-3
T-1-2
1-3