2 Processing Item "Camera Image Input GigE"
2-4
Camera Image Input GigE Timing
Chart
This section includes the timing chart for measurement executed with the TRG input of the camera.
Precautions for Correct Use
As shown in the figure below, the Measurement time displayed on the main screen does not
include the Exposure time and Transfer time.
On the other hand, when measurement is executed by the internal Measurement command, the
Measurement time displayed does include those times, so it will be significantly different.
Number of cameras: One, Number of Image Input: Once
Image Conversion process is executed after the Image Transfer from the camera is completed.
Camera
Software
(Measurement Flow)
Number of cameras: One, Number of Image Input: Multiple
TRG Input is required for each Camera Image Input.
The 2nd and subsequent TRG Input must be input within 3 seconds after the end of the previous measurement process.
If TRG is not input within 3 seconds, a timeout error will occur.
Camera
Software
(Measurement Flow)
2-6
TRG Input
Exposure
Image
Measurement time displayed
Transfer
on the main screen
Image
Image
Transfer
Conversion
TRG Input
Exposure
Image
Transfer
Image
Image
Measurement
Transfer
Conversion
FJ Series (Camera & Software Vision Package) PC Vision System Camera Setup Guide (Z428-E1)
Measurement, Output
TRG Input
Exposure
Image
Transfer
Image
Transfer
Image
Measurement, Output