To Output Measurement Values To A Pc Or Plc; To Output Position Information Of Measurement Targets As Actual Coordinates - Omron ZFX-C10 User Manual

Vision sensor with built-in lcd monitor
Hide thumbs Also See for ZFX-C10:
Table of Contents

Advertisement

To Output Measurement Values to a PC or PLC

Measurement values and judgment results can be output to a personal computer, PLC or other external device.
Set the items to output and the output destination.
The following data can be output.
Output Item
Data (measurement val-
ues)
Judgment
• Setting Output Content p.116
• Assigning the Data Output Destination p.117
To Output Position Information of Measurement
Targets as Actual Coordinates
As the controller default, measurement values are output in pixel units and camera coordinates. You can
convert measurement results in pixels to actual dimensions (
enabling the calibration function.
Calibration p.88
44
Troubleshooting
Output Destination
Serial interface (RS-232/RS-422, USB)
Parallel interface
SD card
Parallel interface
m or mm) or actual coordinates for output by
µ
ZFX-C User's Manual