2.
Set up the judgement condition.
2
Setting item
Density
average
Destiny
deviation

Output Parameters (Color Data)

Specifies whether or not the judgement results of this processing unit is reflected in the scene overall
judgement.
1.
Tap [Output parameter] in the Item Tab area.
2.
Choose whether or not to reflect this in the scene overall judgement in "Reflect to overall
judgement" area.
Setting item
Reflect to overall
judgement

Key Points for Test Measurement and Adjustment (Color Data)

The following content can be confirmed in the "Detail result"area using text.
For color cameras
Displayed items
Judge
Average R
Average G
Average B
Color difference
Color deviation
158
Color Data
Set value
Specify the upper and lower limit values for judging the average
0 to 255
density of the measurement region.
Specify the upper and lower limit values for the deviation of the
0 to 127
average density in the measurement region.
Set value
[factory
default]
[ON]
Enables choosing whether or not the judgement results of this
OFF
processing unit is reflected in the scene overall judgement.
Judgement result
R (red) element average value
G (green) element average value
B (blue) element average value
The color difference between the average color and reference color in the
measurement region
Color deviation in the measurement region
Description
Description
Description